COREALIGN
Shaft / core
Lift Shaft 1 (south-west)
Construction height
17,750 mm
Section
#6 complete
Cycle
18420
Camera frame spread
Last valid position
unavailable
Motion
SETTLED · 0.00 mm RMS
Coordinate system
Embassy Gardens site grid (local, mm)

POSITION NOT VERIFIED

Awaiting first camera read cycle from CoreAlign Gateway.

  • No position has been calculated yet.

Demonstration thresholds in use (0–10 normal, 10–15 warning, 15–20 high, 20–25 critical, 25 mm+ outside permitted tolerance). Real thresholds must be configured and approved by the project's competent engineer or surveyor.

X deviation
mm
Y deviation
mm
Total horizontal
mm
Permitted 25 mm
Z deviation
mm
Worst laser residual
mm
Pitch
°
Limit ±0.15°
Roll
°
Limit ±0.15°
Yaw
°
Limit ±0.25°
Pose quality
0 lasers used · RMS — mm
Tilt sensor (source of pitch/roll)
° p/r
Top-down view — plan
L1L2L3L4N
— design shaft / shutter, laser heads— measured shutter + plates— tolerance boundary (25 mm)Spots read this cycle: 0

Deviation visually exaggerated ×40 — numerical measurements are actual.

Elevation — North / South (pitch)0.000°
SN

Reference wall 2000 mm · current elevation 0 mm · exaggerated ×40

Elevation — East / West (roll)0.000°
WE

Reference wall 2000 mm · current elevation 0 mm · exaggerated ×40

Laser channels — spot position on each plateResidual limit 4 mm
Laser / plateSpot USpot VOff centreEdge marginSpot ØFit residualRead atAgeStatus
L1
PL-L1 · CAM-L1
not usedNO SPOT — BEAM BLOCKED
L2
PL-L2 · CAM-L2
not usedNO SPOT — BEAM BLOCKED
L3
PL-L3 · CAM-L3
not usedNO SPOT — BEAM BLOCKED
L4
PL-L4 · CAM-L4
not usedNO SPOT — BEAM BLOCKED

U and V are the measured spot offsets from the plate centre, in plate axes. Residuals compare each spot against the best-fit shutter position. Excluding a reading never deletes it — the original record and the reason are retained in the audit trail.

Live trend — horizontal deviationCollecting samples…
Start a climb to record trend samples.
Jack cycle & vibrationVIB-01 —
SETTLED — SURVEY DATA TRUSTED
Structure quiet for 0 s since the last stroke. Positions are averaged over settled cycles.
Vibration amplitude0.00 mm RMS ·
Measurement limit 0.35 mmAlarm 1.2 mm
Stroke height
40 mm
Next stroke in
Strokes this shift
0
Risen today
0 / 3000 mm
Settled position (averaged over quiet cycles)
No settled cycle yet — awaiting a quiet measurement.
Climb mode
  • PASSCoreAlign Gateway online
  • PASSPlate cameras online
  • FAILSufficient laser readings (≥ 4)
  • PASSLaser setout verified against control
  • FAILTilt sensor INC-01 online
  • FAILCross-check tilt sensor INC-02 online
  • FAILMeasurement quality acceptable
  • FAILCurrent position established
  • PASSStructure settled (vibration ≤ 0.35 mm RMS)
  • FAILVibration sensor online

PRE-CLIMB CHECKS NOT SATISFIED

Alerts0 active

No active alerts against configured limits.

Hydraulic lift pointsSYNCHRONISED
L1 0L2 0L3 0L4 0L5 0L6 0
PointExtensionΔ averageSpeedStatus
J1 NW0 mm+0.0 mm0 mm/minok
J2 N0 mm+0.0 mm0 mm/minok
J3 NE0 mm+0.0 mm0 mm/minok
J4 SE0 mm+0.0 mm0 mm/minok
J5 S0 mm+0.0 mm0 mm/minok
J6 SW0 mm+0.0 mm0 mm/minok